banner
Products
Exceptional quality and customer-focused mentality
690V Static Var Compensator SVC Scg

690V Static Var Compensator SVC Scg

Static Var Generator (SVG) is a product aimed for Power Factor Correction, Voltage Regulation along with Three-phase Bal;
Basic Info
Model NO. SVG026
Application Range Power Factor Correction
Shell Material Aluminum-Zinc Coated Case
Shell Protection Grade IP30
Brand Huakun
Mounting Type Wall Mounted/Rack Mounted
Power Grid Structure 3p3w/3p4w
Noise Level <65dB
Harmonic Compensation Range 2~50th Harmonic Order
Harmonic Compensation Efficienc > 97%
Usage Harmonic Correciton ,Reactive Var Compensation
Transport Package Wooden Box
Specification 682*567*277cm
Trademark Huakun
Origin Shanghai, China
HS Code 8543709990
Production Capacity 20000PCS/Year
Product Description

690V Static Var Compensator SVC Scg

690V Static Var Compensator SVC Scg

Static Var Generator (SVG) is a product aimed for Power Factor Correction, Voltage Regulation along with Three-phase Balancing Function. SHHKK-SVG can do bi-directional power factor correction, PF from 1.0 inductive to 1.0 capacitive. Benefiting from inverter technology, SVG compensation is stepless, which means SVG output shall match the system reactive power, no over-compensation or under compensation. For single module, SVG capacity ranges from 35kvar to 150kvar. For cabinet system, it's unlimited parallel design . Compared with the traditional capacitor bank, SVG has the advantages of fast response and highcompensation accuracy without under-compensation or over-compensation problems.Δ Improved power factor PF ≥ 0.99Δ Compensated inductive or capacitive reactiveΔ Unaffected by harmonics

690V Static Var Compensator SVC Scg

HKK-SVG static var generator is a bridge converter composed of fully controlled power electronic devices for dynamic reactive compensation. The basic principle is that the load current is detected in real time by the external current transformer (CT), and the reactive content of load current is extracted by the internal DSP computing. Finally, the instruction value is calculated to control the PWM signal generator to send the control signal to the internal IGBT, so that the inverter can produce the reactive compensation current to meet the requirement, and finally realize the dynamic reactive compensation.

690V Static Var Compensator SVC Scg

690V Static Var Compensator SVC Scg

System parameters
Rated input wire voltage3 8 0 V(-1 5%~+2 0%)
Grid frequency5 0 / 6 0 H z ( r a n g e : 4 5 H z~6 2 H z)
Number of parallel machines1 ~ 1 0 s e t s
Overall efficiency≥9 7%
Grid structureT h r e e - p h a s e t h r e e - w i r e / t h r e e - p h a s e f o u r - w i r e
Current transformer1 5 0/5~1 0 0 0 0/5
Circuit topologyT r i - l e v e l
P e r f o r m a n c e i n d e x
Response time<1 5 m s
Scope of compensationF r o m - 1 t o 1 , c a p a c i t i v e a n d i n d u c t i v e c o n t i n u i t y i s a d j u s t a b l e
Cooling modeI n t e l l i g e n t a i r c o o l i n g
Noise index<5 6 d B
Send inquiry